Терминален прибор

От HelpSystem
Направо към навигацията Направо към търсенето


Продукт InstalSystem 5
Вид статия FUNKCJA I NARZĘDZIE
Актуално съдържание за версия WYDANIE Rev. 16.0


Description

The article describes usage of the element which may act in projects as units that are not selected among producers' catalogues (e.g. heaters, water heaters, fan-coils, other units performing heating or cooling function on the basis of convection principles).
Terminal units may also serve to simulate parts of an existent installation or of a part predicted to be designed in another part of the project (e.g..: simulate a secondary central heating supplied from a flat station).

Location in the program

  • The Терминален прибор element is available in the program in the Конвекция section on the Главни ленти с инструменти ribbon, for all active Конвекция editing scopes.
    1. Терминален прибор

Description of specific data

Мест. нап. заг.

Local resistance coefficient, kv or pressure loss.

Топлопреминаване

Value selection:

  • Конвекция - impacts the resulting convective heating/cooling output in a given room.
  • Лъчист - impacts the resulting radiant heating/cooling output in a given room.

Разпределение[%]

Percentual contribution in covering room heat demand foreseen for this type of units.

2. Терминален прибор


Темп. загуби в ТП

Decrease or increase of medium temperature in the terminal unit, default value drawn from general data for this type of units..

3. Δθs,О - ТП


Неотчетено в обхвата на топлопотребление

If a unit has been drawn within a room, and it is e.g. a water heater, its thermal output may be excluded from the room thermal balance.

Terminal unit sizing

The program does not perform sizing of such units; thus, the obtained thermal output and Темп. загуби в ТП are always equal to the values that have been input.