<br class="iwlinks"/>[[pl:Projektowanie instalacji z zastosowaniem stacji mieszkaniowych|Projektowanie instalacji z zastosowaniem stacji mieszkaniowych]][[zh-cn:采用户用换热机组作为热源的供热系统以及给水系统的设计|采用户用换热机组作为热源的供热系统以及给水系统的设计]] | <br class="iwlinks"/>[[pl:Projektowanie instalacji z zastosowaniem stacji mieszkaniowych|Projektowanie instalacji z zastosowaniem stacji mieszkaniowych]][[en:Designing installations with flat stations|Designing installations with flat stations]][[zh-cn:采用户用换热机组作为热源的供热系统以及给水系统的设计|采用户用换热机组作为热源的供热系统以及给水系统的设计]] | ||
Версия от 23:55, 17 февруари 2021
| Продукт | InstalSystem 5 |
| Вид статия | Софтуерни приложения |
| Актуално съдържание за версия | GOLD rev. 17.0 |
Обхват на урока
Статията показва как да проектирате инсталации с помощта на плоски станции. Последното може да се превърне в точка за свързване на отопление и водоснабдяване на апартаменти.
Асинхронизирането на флуида за отопление с битова гореща вода се взема предвид при оразмеряване на захранващата система на плоска станция. Типът и размерът на плоската станция се избират от потребителя, като междувременно програмата диагностицира дали дадена плоска станция е в състояние да достави достатъчно мощност към отоплителната система, към която е свързана, и за декларирани / изчислени параметри за битова гореща вода.
Modules and program configuration
- InstalSystem 5 package with the following modules:
and as an option:- - if the station is supposed to supply an apartment radiant system with heating medium
- - if calculations for the flat station and the supply system should include flow rate of a sanitary system designed with InstalSystem 5
Initial state
The project contains a building structure (storeys, rooms) and a storey plan drawing.
Room heat load values for heating has been declared.
За повече информация, моля вижте: Preparation of building structure
За повече информация, моля вижте: Import underlay files
Steps to perform - Scenario I - value declared manually
Defining catalogues and general data
| Project files
|
Initial state, isproj Installation containing flat stations in a multifamily building, isproj |
| Designed with | InstalSystem 5 Rev. 17.0 |
| Required modules | Flat stations Heating systems Radiant loop systems Radiators sizing |
| Project range | heating systems, sanitary systems |
| Used catalogues |
Basic radiant systems |
| Type of building | residential building present 4-storey |
| Building structure | Underlay basement, dwg Underlay groundfloor, dwg Underlay floor, dwg Underlay attic, dwg |
| Drawings range | Plan views |
| Prepared by | www.instalsoft.com |
| Legal disclaimer | Possibility to copy the whole projects or its fragments |
| Calculation results | Full calculation results, xls Full printout, pdf General heating results, pdf General water supply system results, pdf Bill of materials, pdf |
| Drawing results | Basement, dwg Groundfloor, dwg Floor, dwg Basement, pdf Ground floor, pdf Floor, pdf |
window
- tab – read the catalogue containing flat stations.
- / tab - complete and other general data, in particular:
Editing installation
Inserting and graphic editing of flat stations
- Choose the / editing scope.
- Insert a flat station using the button. Turn to a chosen angle, if needed.

2. Inserting - / editing scope
Verification and completion of installation data
- In the window , verify data of each element in scope of:
Connecting flat stations
- Connect heating system medium feed and return on the primary side to the place indicated by the symbol
. За повече информация, моля вижте: Connecting storeys with the "Stack" element - Connect radiant system feed and return to the place indicated by the symbol
, created according to the following article:Designing of radiant heating floor and wall installation. - Connect radiator heating system feed and return to the place indicated by the symbol
, created according to the following article: Designing heating systems with convective radiators.
(optional) Copying elements with/without apartment systems on other storeys
Installation copying
- Select and/or chosen system elements.
- Copy selected elements on neighbouring storeys with the function /.
Creating a copy of a whole storey
window
- / tab - select a storey and press .
Verification of installation structure correctness
- Verify correctness of the installation structure with the function (shortcut: Shift + F2).
- Verify correctness of the installation structure and detect collisions using .
За повече информация, моля вижте: Verification of the correctness of installation structure
Calculation performance and verification
- Perform full calculation by clicking the calculator icon
situated in the section on the toolbar. - Verify diagnostics and calculation results, in particular:
За повече информация, моля вижте: Calculations and diagnostics
Printout/export of results
- Print/export drawings.
- Print/export tables.
За повече информация, моля вижте: Export / print results and drawings
Steps to perform - Scenario II - value calculated by the module
Defining catalogues and general data
window
- Zakres projektu tab - check.

7. Declarated project scope. - tab – read the catalogue containing flat stations.
- / tab - complete and other general data, in particular:
- (),
- ()
- : "" or ""
- for "" - the () value is declared manually in the field below and in the window after inserting stations on the drawing

8. User-specified hot water outflow - for "" - the () value will be calculated on the basis of the flat station connected sanitary system flow rate, according to the calculation norm selected in the module. Additionally, it is possible to choose the method of dimensioning the water supply system ( "" or "").

9. Declaring manner of defining hot water outflow
- for "" - the () value is declared manually in the field below and in the window after inserting stations on the drawing
Editing installation
Inserting and graphic editing of flat stations
- Choose the Water supply editing scope.
- Insert the flat station using the icon.

10. Inserting - Water supply
Verification and completion of installation data
- In , verify data of each element in scope of:
- ,
- ,
- (ATTENTION! If, in the window, the option is selected, this value is calculated automatically),
- (ATTENTION! The input temperature of domestic hot water feeding the flat station results from properties of a given producer's heat exchanger, and it usually amounts to 10°C),
- accessories and their data .

11. Editing - Data table
Connecting flat stations
- Connect heating system medium feed and return on the primary side to the place indicated by the symbol
. За повече информация, моля вижте: Connecting storeys with the "Stack" element - Connect radiant system feed and return to the place indicated by the symbol
, created according to the following article:Designing of radiant heating floor and wall installation. - Connect radiator heating system feed and return to the place indicated by the symbol
, created according to the following article: Designing heating systems with convective radiators - Connect medium inflow for the sanitary system as well as sanitary system feed and return to the place indicated by the symbol
, created according to the following article:Designing of water supply system installation.
Verification of installation structure correctness
Steps to perform just like in Scenario I - value declared manually.
Calculation performance and verification
Steps to perform just like in Scenario I - value declared manually.
Printout/export of results
Steps to perform just like in Scenario I - value declared manually.